DD30CRTA Lead Acid Battery Charger 12V with Trickle and Float Charge

DD30CRTA Lead Acid Battery Charger 12V with Trickle and Float Charge

DD30CRTA Lead Acid Battery Charger 12V with Trickle and Float Charge

715.00 (605.93 + GST)

In stock

715.00 (605.93 + GST)

  • Power supply voltage: 15-28VDC(Recommended 16-25VDC)
  • Over  Charge Voltage is 14.8V
  • Float Charge Voltage is 13.55V
  • Maximum charge current: 3A
  • Quiescent current: about 1.8mA
  • High PWM Switching Frequency:300KHz
  • Operating Ambient Temperature: -40℃ to +85℃
  • Size: 66 x 20x 12mm
  • Weight: 9g
Availability: Only 2 left in stock SKU: 3715 Category:
Buy this product to earn 7 Maker Points worth ₹7.
View cart

Description

The Regulation Voltage in Over Voltage Mode and Float Charge Mode
The regulation voltage VOC at BAT pin in overcharge mode is set at 14.8V(Typical) with ±1.5% accuracy.
In float charge mode, the regulation voltage VFLOAT at BAT pin is 91.57% of that in overcharge mode, which is 13.55V(Typical).
Trickle Charge Mode At the beginning of a charge cycle, if the battery voltage is below 75%×VOC, the charger goes into trickle
charge mode with the charge current set at about 17.5% of the constant current.
2: End-of-Over Charge Current
When the battery voltage approaches the over-charge voltage, the charger goes into the overcharge mode. In
overcharge mode, the charge current start to decrease and when the charge current drops to 38% of constant
charge current, the charger goes into float-charge mode.
3: Float Charge Mode
After the overvoltage charge is terminated, the charger goes into float charge mode. In float charge mode, the
battery voltage is regulated to 91.57%×VOC, namely 13.55V(Typical). Float charge mode can compensate for
the loss of battery power due to self-discharge or external loading.
4: Automatic Battery Recharge
In float mode, if both the battery and the input power supply (wall adapter) are present, a new charge cycle will
begin if the battery voltage drops below 83.95%×VOC due to self-discharge or external loading.
A new charge cycle can also be started manually by plugging off the input supply and reapplying it.